230V Models |
| Power Levels crated at nominal inputs |
1000VA/ 700W;1700VA/ 1200W; |
| 2500VA/ 1800W;3500VA/ 2400W; |
| 4000VA/ 3200W |
| Output Voltage |
200V/220V/230V/240V Selectable |
| Voltage Waveform |
Sine wave |
| Crest Factor |
05:01 |
| Output Frequency |
50/60Hz(selectable by using the remote set-up software) |
| Regulation |
±3% (output voltage adjustable by using the remote set-up software) |
| Transfer time |
2ms typical (Bypass to inverter mode) |
| (Models with AC input) |
Zero (Inverter mode to bypass mode) |
| Over current protection |
Over load alarm level 100% ~ 120% |
| Over load shutdown level 120% ~ 190% |
| (Adjustable by using the remote set-up software) |
| AC Input (optional input) |
| |
230V Models |
| Nominal Voltage |
200V/220V/230V/240V Selectable |
| Input Frequency |
47Hz ~ 65Hz, 50/60Hz auto-sensing |
| Efficiency |
97% (Normal mode) |
| Noise Filtering |
Full time EMI/RFI filtering |
| Over current protection |
By re-settable over current protector |
| Voltage Range |
-30% ~ +33% for selected nominal voltage. |
| AVR Range |
Enhanced Buck: +24% of selected nominal voltage |
| (2 Bucks, 2 Boosts) |
Buck mode: +8% of selected nominal voltage |
| |
Boost mode: -8% of selected nominal voltage |
| |
Enhanced Boost: -20% of selected nominal voltage |
| Surge Protection |
1000VA:220 Joules |
| (Only available when AC Input included) |
1700VA / 2500VA:440 Joules |
| |
3500VA / 4000VA:660 Joules |
| DC Input |
| Voltage |
24Vdc(20Vdc ~ 32Vdc):1000VA / 1700VA |
| 48Vdc(40Vdc ~ 64Vdc): 1000VA / 1700VA / 2500VA / 3500VA |
| 72Vdc(60Vdc ~ 96Vdc): 1700VA / 2500VA / 3500VA |
| 96Vdc(80Vdc ~128Vdc): 1700VA / 2500VA / 3500VA |
| 108Vdc(90Vdc ~ 144Vdc):1700VA / 2500VA / 3500VA / 4000VA |
| Typical run time |
Load <100%, No Limit |
| 100%<Load<120%, 30 minutes typical |
| 120%<Load<190%, 1 minute maximum |
| 190%<Load, 0.25 second typical |
| Protection |
Input polarity protection (by DC relay) |
| DC fuse protection (60A or 120A, depends on DC voltage and VA rating) |
| Over current protection (2KHz Switching, real time protection) |
| Under voltage protection |
| Over voltage protection (CPU control) |
| Monitoring |
Smart monitoring & warning for failed battery |
| Communications & Management |
| Interface port |
UPSilon2000 compatible; optional for RS232 and/or USB |
| Control panel |
LCD or LED Selectable (Rack units with LCD only) |
| Audible alarm |
Alarm on battery:Low battery & Battery over voltage |
| Alarm on abnormal operation:Over load, Short-circuit, & Over heat |
| Green mode function (for models with AC input) |
1% to 14% of full load (adjustable by using the remote set-up software) |
| The default setting is OFF. |
| Cooling fan control |
Auto on / off, controlled by temperature & operation mode |
| Environmental and Safety |
| Operating Temperature |
Up to 1500 meters:0℃ to 40℃ (32℉ to 104℉) |
| Transit/storage Temperature |
-15℃ to 55℃ (5℉ to 131℉) |
| Relative Humidity |
5 - 95% non condensing |
| Operating Altitude |
0 ~ 3000 meters |
| Audible noise at 1M from surface of unit |
≦50 dBA |
| Safety Markings |
CE |
| EMC |
Class A, EN50091-2, FCC part15, IEC1000-2-2 |
| Isolation |
3KVac for 1 minute between DC input and AC output |
| Quality control system |
ISO 9001 |
| Physical |
Dimensions: Unit / Shipping D×H×W (cm) |
Tower (TAT) |
Rack (TAR) |
1000VA/ 1700VA/ 2500VA: 45 x 20 x 18 cm / 54 x 33 x 30 cm 3500VA/ 4000VA: 51 x 20 x 18/61 x 33 x 30 cm |
1000VA/ 1700VA/ 2500VA/ 3500VA: 3u x 45 cm / 59 x 33 x 59 cm 4000VA: 4u x 45 cm / 59 x 38 x 59 cm |
Weight: Net / Gross (kg) |
1000VA:16 / 17 (kg) |
1000VA :20 / 24 (kg) |
| 1700VA:19 / 20 (kg) |
1700VA :26 / 30 (kg) |
| 2500VA:23 / 24 (kg) |
2500VA/ 3500VA :34 / 38 (kg) |
| 3500VA:31 / 33 (kg) |
4000VA:48 / 52 (kg) |
| 4000VA:43 / 45 (kg) |
|
| Packing |
Export carton for each unit, 16 - 30 units per pallet |